Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Certification: | CE |
| Working Medium: | R32 |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
R32 Swimming pool heat pump
Offering a range of high quality pool heat pump products, we are committed to providing the top pool essentials for our customers to enjoy stress-free pool time all year round.R32 pool heat pump its shell is made of plastic ABS material, this pool heat pump is mainly used in coastal countries or regions of the market, can effectively avoid the impact of Marine climate caused by corrosion. Suitable for swimming pools and spa pools from 15 cubic meters to 100 cubic meters. With the air to water Swimming Pool Heater heat pump, your water park is right in front of you, quality commitment, enjoyment.
ECO-friendly refrigerant
Four-season Swimming
Main Components
--Electronic Expansion Valve
Easy Control

Quiet Operation


R32 swimming pool heat pump achieves completely soft switching at the start-up stage from an intensity of 0A to28Aat maximum), while the traditional ON/0fF heat pumps start in a current intensity over three times higher, which will greatly impact the family electricity system.
| Power Supply | 220-240V~/ 50Hz | 220-240V~/ 50Hz | 380-415V/3N~/50Hz | ||||||||||
| Performance Condition: Ambient Temperature: (DB/WB) 27°C/24.3°C; Water Inlet/Outlet Temperature: 24°C/26°C. | |||||||||||||
| Heating Capacity (kW) | 3.00~5.90 | 4.57~7.58 | 5.06~9.40 | 5.48~11.07 | 6.84~15.01 | 7.58~17.28 | 9.45~22.85 | 10.84~25.06 | 9.87~22.61 | 10.99~25.23 | 14.28~28.24 | ||
| Consumed Power (kW) | 0.34~0.78 | 0.55~1.14 | 0.60~1.36 | 0.61~1.45 | 0.79~2.12 | 0.86~2.44 | 1.06~3.00 | 1.24~3.53 | 1.11~3.01 | 1.25~3.54 | 1.69~4.42 | ||
| COP | 8.82~7.56 | 8.31~6.65 | 8.43~6.92 | 8.98~7.64 | 8.66~7.08 | 8.81~7.07 | 8.91~7.61 | 8.74~7.10 | 8.89~7.51 | 8.79~7.13 | 8.45~6.39 | ||
| Boost Mode | Heating Capacity (kw) | 5.9 | 7.58 | 9.4 | 11.07 | 15.01 | 17.28 | 22.85 | 25.06 | 22.61 | 25.23 | 28.24 | |
| COP | 7.56 | 6.65 | 6.92 | 7.64 | 7.08 | 7.07 | 7.61 | 7.1 | 7.51 | 7.13 | 6.39 | ||
| Smart Mode | Heating Capacity (kW) | 4.5 | 5.8 | 7.8 | 9.1 | 11.55 | 14.01 | 17 | 20.4 | 17 | 20.4 | 22.61 | |
| COP | 8.21 | 7.76 | 7.88 | 8.37 | 8.11 | 8.16 | 8.23 | 8.14 | 8.34 | 8.19 | 8.03 | ||
| Silent Mode | Heating Capacity (kW) | 3 | 4.57 | 5.06 | 5.48 | 6.84 | 7.58 | 9.45 | 10.84 | 9.87 | 10.99 | 14.28 | |
| COP | 8.82 | 8.31 | 8.43 | 8.98 | 8.66 | 8.81 | 8.91 | 8.74 | 8.89 | 8.79 | 8.45 | ||
| Performance Condition: Ambient Temperature: (DB/WB) 15°C/12°C; Wate Outlet Temperature: 26°C. | |||||||||||||
| Heating Capacity (kW) | 1.76~4.55 | 3.00~6.57 | 3.15~6.48 | 3.67~8.04 | 4.01~9.68 | 5.48~12.28 | 7.88- 16.75 | 9.87~18.95 | 8.14~16.21 | 10.05~19.14 | 11.11~21.31 | ||
| Consumed Power (kW) | 0.26~0.92 | 0.46~1.32 | 0.47~1.35 | 0.52~1.46 | 0.58~1.91 | 0.77~2.40 | 1.07~3.06 | 1.33~3.51 | 1.12~2.97 | 1.35~3.51 | 1.46~4.05 | ||
| COP | 6.77~4.91 | 6.51~4.98 | 6.61~4.77 | 6.98~5.50 | 6.87~5.06 | 7.05~5.11 | 7.35~5.46 | 7.41~5.39 | 7.21~5.44 | 7.40~5.44 | 7.58~5.26 | ||
| Boost Mode | Heating Capacity (kw) | 4.55 | 6.57 | 6.48 | 8.04 | 9.68 | 12.28 | 16.75 | 18.95 | 16.21 | 19.14 | 21.31 | |
| COP | 4.91 | 4.98 | 4.77 | 5.5 | 5.06 | 5.11 | 5.46 | 5.39 | 5.44 | 5.44 | 5.26 | ||
| Smart Mode | Heating Capacity (kW) | 3.1 | 4.3 | 6.1 | 6.58 | 8.65 | 10.55 | 11.2 | 13.5 | 11.2 | 13.5 | 14.63 | |
| COP | 6.05 | 6.14 | 6.22 | 6.4 | 6.2 | 6.16 | 6.2 | 6.21 | 6.2 | 6.21 | 6.18 | ||
| Silent Mode | Heating Capacity (kW) | 1.76 | 3 | 3.15 | 3.67 | 4.01 | 5.48 | 7.88 | 9.87 | 8.14 | 10.05 | 11.11 | |
| COP | 6.77 | 6.51 | 6.61 | 6.98 | 6.87 | 7.05 | 7.35 | 7.41 | 7.21 | 7.4 | 7.58 | ||
| Performance Condition: Ambient Temperature: (DB/WB) 35°C/-; Water Inlet/Outlet Temperature: 30°C/28°C. | |||||||||||||
| Cooling Capacity (kW) | 1.53~3.00 | 1.85~3.32 | 2.05~5.66 | 2.01~5.48 | 2.98~7.27 | 4.11~10.29 | 5.48 - 12.82 | 7.54 ~12.61 | 5.68 ~13.01 | 7.59 ~ 12.70 | 8.15~14.54 | ||
| Consumed Power (kW) | 0.43~1.23 | 0.48~1.33 | 0.48~1.77 | 0.44~1.68 | 0.61~2.31 | 0.87~3.65 | 1.07~4.16 | 1.41~3.75 | 1.10~4.28 | 1.40~3.72 | 1.68~4.92 | ||
| EER | 3.52~2.43 | 3.84~2.49 | 4.25~3.18 | 4.57~3.25 | 4.88~3.14 | 4.72~2.82 | 5.10~3.08 | 5.34~3.36 | 5.12~3.04 | 5.40~3.41 | 4.84~2.95 | ||
| Boost Mode | Heating Capacity (kw) | 3 | 3.32 | 5.66 | 5.48 | 7.27 | 10.29 | 12.82 | 12.61 | 13.01 | 12.7 | 14.54 | |
| COP | 2.43 | 2.49 | 3.18 | 3.25 | 3.14 | 2.82 | 3.08 | 3.36 | 3.04 | 3.41 | 2.95 | ||
| Smart Mode | Heating Capacity (kW) | 2.3 | 2.92 | 3.5 | 4.89 | 6.45 | 7.77 | 8.89 | 9.8 | 8.92 | 9.8 | 10.55 | |
| COP | 2.95 | 3.08 | 3.76 | 3.84 | 3.93 | 3.88 | 4.05 | 4.36 | 4.08 | 4.4 | 4.13 | ||
| Silent Mode | Heating Capacity (kW) | 1.53 | 1.85 | 2.05 | 2.01 | 2.98 | 4.11 | 5.48 | 7.54 | 5.68 | 7.59 | 8.15 | |
| COP | 3.52 | 3.84 | 4.25 | 4.57 | 4.88 | 4.72 | 5.1 | 5.34 | 5.12 | 5.4 | 4.84 | ||
| Max. Power Input (kW) | 1.31 | 1.61 | 1.75 | 2.3 | 3.2 | 3.9 | 4.1 | 4.5 | 4.1 | 4.5 | 5.4 | ||
| Max. Current (A) | 5.95 | 7.32 | 7.96 | 10.5 | 14.5 | 17.7 | 18.8 | 19.5 | 7.3 | 8.5 | 10.2 | ||
| Advised Pool Volume (m³) | 10~20 | 15~30 | 20~40 | 25~50 | 30~60 | 35~70 | 45~80 | 55~90 | 45~80 | 55~90 | 65~100 | ||
| Running Ambient Temp. Range ( ºC ) | -10~43 | ||||||||||||
| Heating Temperature Range ( ºC ) | 15~35 | ||||||||||||
| Cooling Temperature Range ( ºC ) | 8~28 | ||||||||||||
| Refrigerant | R32 | ||||||||||||
| Compressor Type | Rotary | ||||||||||||
| Compressor Brand | GMCC / Mitsubishi / Panasonic | ||||||||||||
| Gas Control | EEV | ||||||||||||
| 4-Way Valve | Yes | ||||||||||||
| Fan Quantity | 1 | ||||||||||||
| Heat Exchanger | Titanium in PVC | ||||||||||||
| Casing Material | ABS Plastic /Galvanized Sheet | ||||||||||||
| Water Pipe Connection (mm) | 50 | ||||||||||||
| Sound Pressure 1m dB (A) | 43 | 45 | 47 | 47 | 48 | 49 | 50 | 52 | 51 | 53 | 54 | ||
| Water Flow Volume (m³/h) | 2.0~3.0 | 2.5~3.5 | 3.0~4.0 | 4.0~5.5 | 5.5~7.0 | 7.0~8.5 | 8.5~10 | 10.0~11.5 | 8.5~10 | 10.0~11.5 | 11.5~13 | ||
| Water Pressure Drop (kpa) | 15 | 17 | 18 | 15 | 18 | 23 | 32 | 35 | 32 | 35 | 38 | ||
| Electric Shock Proof | CLASS I | ||||||||||||
| Water Proof Level | IPX4 | ||||||||||||
| Unit weight(Kg) | 40 | 45 | 46 | 53 | 58 | 62 | 82 | 87 | 85 | 90 | 93 | ||
| Unit Dimensions(L*W*H) (mm) | 940 ×382×632 | 1030×427×672 | 1160×477×772 | ||||||||||
Guanadong Luckingstar New Energy Co., ltd, as one of the top 10 heat pump brands from China, has beendedicated to producing high-qualitly heat pumps since its establishment in 2006. Luckingstar heat pumpfactory covers an extensive area of 75,000 square meters and is equipped with 7 automatic production lines.This substantial infrastructure enables to achieve an annual production capacity of around 500,000 units of heatpumps. Luckingstar places great importance on ensuring the quality of their products, Luckingstar haveestablished 5 professional performance test laboratories specifically desianed for air source and water sourceheat pumps, These state-of-the-art laboratories are capable of operating in extreme temperatures as low as-41.5°C and have a capacity range of 1 to 500 kw.Thanks to the unwavering commitment to quality,Luckingstar heat pumps have gained popularity worldwide and have been successfully exported to more than40countries including Europe, Asia, Africa ,Australia and America etc.areas.